{"id":7229,"date":"2023-03-15T20:16:46","date_gmt":"2023-03-15T20:16:46","guid":{"rendered":"https:\/\/arrotek.wpenginepowered.com\/guidewires-essential-design-considerations\/"},"modified":"2025-12-08T16:35:39","modified_gmt":"2025-12-08T16:35:39","slug":"guidewires-essential-design-considerations","status":"publish","type":"post","link":"https:\/\/arrotek.com\/en\/guidewires-essential-design-considerations\/","title":{"rendered":"Guide-wires \u2013 Essential Design Considerations"},"content":{"rendered":"\n<p>Guidewires are an essential component of many <a href=\"https:\/\/arrotek.com\/en\/minimally-invasive-medical-devices\/\">minimally invasive medical devices<\/a>, including many <a href=\"https:\/\/arrotek.com\/en\/advanced-catheter-technologies-2\/\">advanced catheter products<\/a>. There are multiple types of guidewires available, with different technologies, materials, designs, and performance characteristics. In this blog, we\u2019ll look at the essential design features that should be considered when looking at guidewires for your product.<\/p>\n\n<p>Guide-wires are designed to navigate often tortuous vasculatures to reach target treatment or diagnostic sites within the body. They are also used in the placement of interventional devices, and they enable the placement of catheter devices while also helping to stabilize and precisely position catheters at the target location. <\/p>\n\n<p>Therefore, guidewires are essential to the successful completion of a range of different medical procedures. If you are <a href=\"https:\/\/arrotek.com\/en\/catheter-design-and-development-key-considerations-to-get-your-product-to-market\/\">developing a new catheter<\/a> or another type of medical device, guidewires are a crucial component. Here are the <a href=\"https:\/\/arrotek.com\/en\/medical-device-product-design-arrotek\/\">essential design considerations<\/a> that you need to be aware of.<\/p>\n\n<h2 class=\"wp-block-heading\">Guide-wire Performance Characteristics<\/h2>\n\n<figure class=\"wp-block-image size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"341\" src=\"https:\/\/arrotek.com\/wp-content\/uploads\/2024\/03\/Guidewire-Performance-Characteristics-1024x341.jpg\" alt=\"Guide-wire Performance Characteristics\" class=\"wp-image-4314\" srcset=\"https:\/\/arrotek.com\/wp-content\/uploads\/2024\/03\/Guidewire-Performance-Characteristics-1024x341.jpg 1024w, https:\/\/arrotek.com\/wp-content\/uploads\/2024\/03\/Guidewire-Performance-Characteristics-300x100.jpg 300w, https:\/\/arrotek.com\/wp-content\/uploads\/2024\/03\/Guidewire-Performance-Characteristics-768x256.jpg 768w, https:\/\/arrotek.com\/wp-content\/uploads\/2024\/03\/Guidewire-Performance-Characteristics.jpg 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<p>There are a number of performance characteristics that are important when designing or choosing a guide-wire for your minimally invasive medical device.<\/p>\n\n<h3 class=\"wp-block-heading\">Push Control<\/h3>\n\n<p>Push control (often referred to as pushability) is the ability to push the guide-wire through vessels to reach the target location.<\/p>\n\n<h3 class=\"wp-block-heading\">Steerability<\/h3>\n\n<p>The responsiveness of the guide-wire tip as the clinician steers the guide-wire through the body&#8217;s vasculature. Both steerability and push control are part of the guide-wire\u2019s trackability. <\/p>\n\n<h3 class=\"wp-block-heading\">Torque Control<\/h3>\n\n<p>Torque control is the responsiveness of the guide-wire to turn inside vessels as the clinician applies rotational force. The ideal objective in most situations is 1:1 torque, where the rotational force applied by the clinician at the proximal end of the guide-wire is translated at a 1:1 ratio at the distal tip. <\/p>\n\n<h3 class=\"wp-block-heading\">Flexibility<\/h3>\n\n<p>The ability of the guide-wire to maintain trackability and torque control while flexing on its longitudinal axis.<\/p>\n\n<h3 class=\"wp-block-heading\">Opacity<\/h3>\n\n<p>The visibility of the guide-wire to the clinician as it is being navigated through the body to the target location. Visibility is typically achieved under fluoroscopic imaging. For some applications, radiopaque markings are required along the guide-wire to offer enhanced visibility.  <\/p>\n\n<h2 class=\"wp-block-heading\">Catheter Guide-wire Design Considerations<\/h2>\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"341\" src=\"https:\/\/arrotek.com\/wp-content\/uploads\/2024\/03\/Guidewire-Design-Considerations-1024x341.jpg\" alt=\"Guide-wire Design Considerations\" class=\"wp-image-4315\" srcset=\"https:\/\/arrotek.com\/wp-content\/uploads\/2024\/03\/Guidewire-Design-Considerations-1024x341.jpg 1024w, https:\/\/arrotek.com\/wp-content\/uploads\/2024\/03\/Guidewire-Design-Considerations-300x100.jpg 300w, https:\/\/arrotek.com\/wp-content\/uploads\/2024\/03\/Guidewire-Design-Considerations-768x256.jpg 768w, https:\/\/arrotek.com\/wp-content\/uploads\/2024\/03\/Guidewire-Design-Considerations.jpg 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<h3 class=\"wp-block-heading\">Guide-wire Tips<\/h3>\n\n<p>The tip is one of the most important components of a guide-wire as the design needs to prevent the perforation of vessel walls while facilitating the navigation of the guide-wire through the required vasculatures.<\/p>\n\n<p>There are various tip shapes that are possible, including J-curve or straight tips, as well as different levels of rigidity\/flexibility. J-tip variations can be designed to straighten when required. <\/p>\n\n<p>Tip shape retention is a key characteristic for many applications, where the tip can flex while tracking through vessels, before returning back to its original shape.<\/p>\n\n<h3 class=\"wp-block-heading\">Core Taper<\/h3>\n\n<p>Guide-wires have two main elements \u2013 the core and the tip. How the guidewire&#8217;s core tapers to the tip is an important consideration, especially in relation to the length of the core taper. In general, short tapers provide added support while long tapers are easier to track.  <\/p>\n\n<h3 class=\"wp-block-heading\">Lubricity<\/h3>\n\n<p>The addition of a hydrophilic coating to the guide-wire reduces friction as it is tracked to the target location.<\/p>\n\n<h3 class=\"wp-block-heading\">Tactile Feel<\/h3>\n\n<p>High levels of tactile feel make it easier for the clinician to navigate the guide-wire. However, there is often an inverse relationship between tactile feel and lubricity (see the above point on lubricity). Greater lubricity reduces friction as the guide-wire passes through vessels, but it also reduces tactile feedback.  <\/p>\n\n<h3 class=\"wp-block-heading\">Braiding and Coiling<\/h3>\n\n<p>The addition of braiding or coiling over the core wire increases the flexibility of the guide-wire and improves its ability to return back to shape.<\/p>\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"341\" src=\"https:\/\/arrotek.com\/wp-content\/uploads\/2024\/03\/Coiling-over-the-core-wire-with-radiopaque-tip-1024x341.jpg\" alt=\"Coiling over the core wire with radiopaque tip\" class=\"wp-image-4316\" srcset=\"https:\/\/arrotek.com\/wp-content\/uploads\/2024\/03\/Coiling-over-the-core-wire-with-radiopaque-tip-1024x341.jpg 1024w, https:\/\/arrotek.com\/wp-content\/uploads\/2024\/03\/Coiling-over-the-core-wire-with-radiopaque-tip-300x100.jpg 300w, https:\/\/arrotek.com\/wp-content\/uploads\/2024\/03\/Coiling-over-the-core-wire-with-radiopaque-tip-768x256.jpg 768w, https:\/\/arrotek.com\/wp-content\/uploads\/2024\/03\/Coiling-over-the-core-wire-with-radiopaque-tip.jpg 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<h3 class=\"wp-block-heading\">Stiffness Versus Flexibility<\/h3>\n\n<p>Greater stiffness provides more support for the catheter, for example, while greater flexibility enables the navigation of more complex vasculatures. In terms of flexibility, the goal is often to achieve a no-memory effect to ensure there is no pressure on vessel walls during procedures. <\/p>\n\n<h3 class=\"wp-block-heading\">Tip Load<\/h3>\n\n<p>The force needed to bend the tip.<\/p>\n\n<h3 class=\"wp-block-heading\">Crossing Ability<\/h3>\n\n<p>This is the ability of the guide-wire to navigate obstructions, as well as the ability of the catheter to navigate through or by the same obstacles when being passed over the guide-wire. In other words, it is not enough for the guide-wire to cross the obstruction if the catheter can&#8217;t then follow. <\/p>\n\n<h3 class=\"wp-block-heading\">Materials<\/h3>\n\n<p>The most common materials used in guide-wires are nitinol or stainless steel. Both offer different performance characteristics. For example, nitinol offers flexibility and kink resistance while stainless steel has excellent torque control characteristics.  <\/p>\n\n<h3 class=\"wp-block-heading\">Length<\/h3>\n\n<p>How long does the guide-wire need to be to reach the target location?<\/p>\n\n<h3 class=\"wp-block-heading\">Diameter<\/h3>\n\n<p>Smaller diameter guide-wires allow for more complex procedures, including those where smaller or more tortuous vessels need to be tracked. Almost all the above guide-wire performance features and characteristics factor into decisions on diameter. <\/p>\n\n<h2 class=\"wp-block-heading\">Guide-wire Expertise at Arrotek<\/h2>\n\n<p>At Arrotek, we offer comprehensive design services for catheters and other minimally invasive medical devices. This includes guide-wires and all other components of your product. We can also call on the expertise and product range of our sister company, <a href=\"https:\/\/galtmedical.com\/\">Galt Medical<\/a>. Galt manufactures and supplies OEM and private-label guide-wires. To discuss your project in the strictest confidence, <a href=\"https:\/\/arrotek.com\/en\/contact\/\">please get in touch<\/a>.    <\/p>\n","protected":false},"excerpt":{"rendered":"<p>Guidewires are an essential component of many minimally invasive medical devices, including many advanced catheter products. There are multiple types of guidewires available, with different technologies, materials, designs, and performance characteristics. In this blog, we\u2019ll look at the essential design features that should be considered when looking at guidewires for your product. Guide-wires are designed <a href=\"https:\/\/arrotek.com\/en\/guidewires-essential-design-considerations\/\" class=\"more-link\">&#8230;<span class=\"screen-reader-text\">  Guide-wires \u2013 Essential Design Considerations<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":6113,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"content-type":"","footnotes":""},"categories":[24],"tags":[],"class_list":["post-7229","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge-hub-en"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Guide-wires \u2013 Essential Design Considerations - Arrotek | Medical Device Innovation<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/arrotek.com\/en\/guidewires-essential-design-considerations\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Guide-wires \u2013 Essential Design Considerations - Arrotek | Medical Device Innovation\" \/>\n<meta property=\"og:description\" content=\"Guidewires are an essential component of many minimally invasive medical devices, including many advanced catheter products. There are multiple types of guidewires available, with different technologies, materials, designs, and performance characteristics. In this blog, we\u2019ll look at the essential design features that should be considered when looking at guidewires for your product. Guide-wires are designed ... Guide-wires \u2013 Essential Design Considerations\" \/>\n<meta property=\"og:url\" content=\"https:\/\/arrotek.com\/en\/guidewires-essential-design-considerations\/\" \/>\n<meta property=\"og:site_name\" content=\"Arrotek | Medical Device Innovation\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/arrotek\" \/>\n<meta property=\"article:published_time\" content=\"2023-03-15T20:16:46+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-12-08T16:35:39+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/arrotek.com\/wp-content\/uploads\/2024\/03\/Guidewires-\u2013-Essential-Design-Considerations.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"628\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Arrotek\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@arrotekmedical\" \/>\n<meta name=\"twitter:site\" content=\"@arrotekmedical\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Arrotek\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/arrotek.com\/en\/guidewires-essential-design-considerations\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/arrotek.com\/en\/guidewires-essential-design-considerations\/\"},\"author\":{\"name\":\"Arrotek\",\"@id\":\"https:\/\/arrotek.com\/en\/#\/schema\/person\/4f47ea0cebc535d2417dd1d0b15e72e0\"},\"headline\":\"Guide-wires \u2013 Essential Design Considerations\",\"datePublished\":\"2023-03-15T20:16:46+00:00\",\"dateModified\":\"2025-12-08T16:35:39+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/arrotek.com\/en\/guidewires-essential-design-considerations\/\"},\"wordCount\":845,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/arrotek.com\/en\/#organization\"},\"image\":{\"@id\":\"https:\/\/arrotek.com\/en\/guidewires-essential-design-considerations\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/arrotek.com\/wp-content\/uploads\/2024\/03\/Guidewires-\u2013-Essential-Design-Considerations.jpg\",\"articleSection\":[\"Knowledge Hub\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/arrotek.com\/en\/guidewires-essential-design-considerations\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/arrotek.com\/en\/guidewires-essential-design-considerations\/\",\"url\":\"https:\/\/arrotek.com\/en\/guidewires-essential-design-considerations\/\",\"name\":\"Guide-wires \u2013 Essential Design Considerations - Arrotek | Medical Device Innovation\",\"isPartOf\":{\"@id\":\"https:\/\/arrotek.com\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/arrotek.com\/en\/guidewires-essential-design-considerations\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/arrotek.com\/en\/guidewires-essential-design-considerations\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/arrotek.com\/wp-content\/uploads\/2024\/03\/Guidewires-\u2013-Essential-Design-Considerations.jpg\",\"datePublished\":\"2023-03-15T20:16:46+00:00\",\"dateModified\":\"2025-12-08T16:35:39+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/arrotek.com\/en\/guidewires-essential-design-considerations\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/arrotek.com\/en\/guidewires-essential-design-considerations\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/arrotek.com\/en\/guidewires-essential-design-considerations\/#primaryimage\",\"url\":\"https:\/\/arrotek.com\/wp-content\/uploads\/2024\/03\/Guidewires-\u2013-Essential-Design-Considerations.jpg\",\"contentUrl\":\"https:\/\/arrotek.com\/wp-content\/uploads\/2024\/03\/Guidewires-\u2013-Essential-Design-Considerations.jpg\",\"width\":1200,\"height\":628},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/arrotek.com\/en\/guidewires-essential-design-considerations\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/arrotek.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Guide-wires \u2013 Essential Design Considerations\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/arrotek.com\/en\/#website\",\"url\":\"https:\/\/arrotek.com\/en\/\",\"name\":\"Arrotek | Medical Device Innovation\",\"description\":\"Medical device design, development, manufacturing, and regulatory support\",\"publisher\":{\"@id\":\"https:\/\/arrotek.com\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/arrotek.com\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/arrotek.com\/en\/#organization\",\"name\":\"Arrotek | Medical Device Innovation\",\"alternateName\":\"Arrotek\",\"url\":\"https:\/\/arrotek.com\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/arrotek.com\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/arrotek.com\/wp-content\/uploads\/2024\/01\/logo.png\",\"contentUrl\":\"https:\/\/arrotek.com\/wp-content\/uploads\/2024\/01\/logo.png\",\"width\":163,\"height\":53,\"caption\":\"Arrotek | Medical Device Innovation\"},\"image\":{\"@id\":\"https:\/\/arrotek.com\/en\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/arrotek\",\"https:\/\/x.com\/arrotekmedical\",\"https:\/\/www.linkedin.com\/company\/3844874\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/arrotek.com\/en\/#\/schema\/person\/4f47ea0cebc535d2417dd1d0b15e72e0\",\"name\":\"Arrotek\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/secure.gravatar.com\/avatar\/973dfe463ec85785f5f95af5ba3906eedb2d931c24e69824a89ea65dba4e813b?s=96&d=mm&r=g\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/973dfe463ec85785f5f95af5ba3906eedb2d931c24e69824a89ea65dba4e813b?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/973dfe463ec85785f5f95af5ba3906eedb2d931c24e69824a89ea65dba4e813b?s=96&d=mm&r=g\",\"caption\":\"Arrotek\"},\"url\":\"https:\/\/arrotek.com\/en\/author\/admin\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Guide-wires \u2013 Essential Design Considerations - Arrotek | Medical Device Innovation","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/arrotek.com\/en\/guidewires-essential-design-considerations\/","og_locale":"en_US","og_type":"article","og_title":"Guide-wires \u2013 Essential Design Considerations - Arrotek | Medical Device Innovation","og_description":"Guidewires are an essential component of many minimally invasive medical devices, including many advanced catheter products. There are multiple types of guidewires available, with different technologies, materials, designs, and performance characteristics. In this blog, we\u2019ll look at the essential design features that should be considered when looking at guidewires for your product. Guide-wires are designed ... Guide-wires \u2013 Essential Design Considerations","og_url":"https:\/\/arrotek.com\/en\/guidewires-essential-design-considerations\/","og_site_name":"Arrotek | Medical Device Innovation","article_publisher":"https:\/\/www.facebook.com\/arrotek","article_published_time":"2023-03-15T20:16:46+00:00","article_modified_time":"2025-12-08T16:35:39+00:00","og_image":[{"width":1200,"height":628,"url":"https:\/\/arrotek.com\/wp-content\/uploads\/2024\/03\/Guidewires-\u2013-Essential-Design-Considerations.jpg","type":"image\/jpeg"}],"author":"Arrotek","twitter_card":"summary_large_image","twitter_creator":"@arrotekmedical","twitter_site":"@arrotekmedical","twitter_misc":{"Written by":"Arrotek","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/arrotek.com\/en\/guidewires-essential-design-considerations\/#article","isPartOf":{"@id":"https:\/\/arrotek.com\/en\/guidewires-essential-design-considerations\/"},"author":{"name":"Arrotek","@id":"https:\/\/arrotek.com\/en\/#\/schema\/person\/4f47ea0cebc535d2417dd1d0b15e72e0"},"headline":"Guide-wires \u2013 Essential Design Considerations","datePublished":"2023-03-15T20:16:46+00:00","dateModified":"2025-12-08T16:35:39+00:00","mainEntityOfPage":{"@id":"https:\/\/arrotek.com\/en\/guidewires-essential-design-considerations\/"},"wordCount":845,"commentCount":0,"publisher":{"@id":"https:\/\/arrotek.com\/en\/#organization"},"image":{"@id":"https:\/\/arrotek.com\/en\/guidewires-essential-design-considerations\/#primaryimage"},"thumbnailUrl":"https:\/\/arrotek.com\/wp-content\/uploads\/2024\/03\/Guidewires-\u2013-Essential-Design-Considerations.jpg","articleSection":["Knowledge Hub"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/arrotek.com\/en\/guidewires-essential-design-considerations\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/arrotek.com\/en\/guidewires-essential-design-considerations\/","url":"https:\/\/arrotek.com\/en\/guidewires-essential-design-considerations\/","name":"Guide-wires \u2013 Essential Design Considerations - Arrotek | Medical Device Innovation","isPartOf":{"@id":"https:\/\/arrotek.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/arrotek.com\/en\/guidewires-essential-design-considerations\/#primaryimage"},"image":{"@id":"https:\/\/arrotek.com\/en\/guidewires-essential-design-considerations\/#primaryimage"},"thumbnailUrl":"https:\/\/arrotek.com\/wp-content\/uploads\/2024\/03\/Guidewires-\u2013-Essential-Design-Considerations.jpg","datePublished":"2023-03-15T20:16:46+00:00","dateModified":"2025-12-08T16:35:39+00:00","breadcrumb":{"@id":"https:\/\/arrotek.com\/en\/guidewires-essential-design-considerations\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/arrotek.com\/en\/guidewires-essential-design-considerations\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/arrotek.com\/en\/guidewires-essential-design-considerations\/#primaryimage","url":"https:\/\/arrotek.com\/wp-content\/uploads\/2024\/03\/Guidewires-\u2013-Essential-Design-Considerations.jpg","contentUrl":"https:\/\/arrotek.com\/wp-content\/uploads\/2024\/03\/Guidewires-\u2013-Essential-Design-Considerations.jpg","width":1200,"height":628},{"@type":"BreadcrumbList","@id":"https:\/\/arrotek.com\/en\/guidewires-essential-design-considerations\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/arrotek.com\/en\/"},{"@type":"ListItem","position":2,"name":"Guide-wires \u2013 Essential Design Considerations"}]},{"@type":"WebSite","@id":"https:\/\/arrotek.com\/en\/#website","url":"https:\/\/arrotek.com\/en\/","name":"Arrotek | Medical Device Innovation","description":"Medical device design, development, manufacturing, and regulatory support","publisher":{"@id":"https:\/\/arrotek.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/arrotek.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/arrotek.com\/en\/#organization","name":"Arrotek | Medical Device Innovation","alternateName":"Arrotek","url":"https:\/\/arrotek.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/arrotek.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/arrotek.com\/wp-content\/uploads\/2024\/01\/logo.png","contentUrl":"https:\/\/arrotek.com\/wp-content\/uploads\/2024\/01\/logo.png","width":163,"height":53,"caption":"Arrotek | Medical Device Innovation"},"image":{"@id":"https:\/\/arrotek.com\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/arrotek","https:\/\/x.com\/arrotekmedical","https:\/\/www.linkedin.com\/company\/3844874"]},{"@type":"Person","@id":"https:\/\/arrotek.com\/en\/#\/schema\/person\/4f47ea0cebc535d2417dd1d0b15e72e0","name":"Arrotek","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/973dfe463ec85785f5f95af5ba3906eedb2d931c24e69824a89ea65dba4e813b?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/973dfe463ec85785f5f95af5ba3906eedb2d931c24e69824a89ea65dba4e813b?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/973dfe463ec85785f5f95af5ba3906eedb2d931c24e69824a89ea65dba4e813b?s=96&d=mm&r=g","caption":"Arrotek"},"url":"https:\/\/arrotek.com\/en\/author\/admin\/"}]}},"_links":{"self":[{"href":"https:\/\/arrotek.com\/en\/wp-json\/wp\/v2\/posts\/7229","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/arrotek.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/arrotek.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/arrotek.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/arrotek.com\/en\/wp-json\/wp\/v2\/comments?post=7229"}],"version-history":[{"count":0,"href":"https:\/\/arrotek.com\/en\/wp-json\/wp\/v2\/posts\/7229\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/arrotek.com\/en\/wp-json\/wp\/v2\/media\/6113"}],"wp:attachment":[{"href":"https:\/\/arrotek.com\/en\/wp-json\/wp\/v2\/media?parent=7229"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/arrotek.com\/en\/wp-json\/wp\/v2\/categories?post=7229"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/arrotek.com\/en\/wp-json\/wp\/v2\/tags?post=7229"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}